fdsusers@nist.gov wrote:
>
> Kevin
>
> I am grad to see the beta release of the multi-processor version of FDS.
>
> I have successfully run some jobs under Window XP using 2 machines. The
> total memory exceed overcomes 2GB barrier - GREAT.
>
> Some other jobs were unsuccessful. The main reason for the failure may
> be, I guess, is due to the incompatible grids between the two mesh
> blocks. When the memory demand is high, the job fails.
>
> I believe there should be more documentation or recommendation in using
> the multi-mesh-blocks. It seems to be that the name commands TRNX, TRNY
> and TRNZ, which specify the variable grid sizes, can only apply to the
> first block - occur also in version 3. The subsequent blocks do not
> recognise the commands, causing incompatible grid sizes.
>
> So far so good. Thanks for your hard work.
>
Yes, I forgot to add to the manual the keyword MESH_NUMBER,
as in
TRNX ...,MESH_NUMBER=2 /
--
Kevin McGrattan